- Sciencelogic em7 review how to#
- Sciencelogic em7 review serial number#
- Sciencelogic em7 review manual#
- Sciencelogic em7 review password#
- Sciencelogic em7 review iso#
Rough Costs based of 1000 Managed Components (Large Enterprise) The Figure below shows the ScienceLogic VMware view from the vCenter server down through the hosts to the individual VMs.ĮM7 is a big product, I’m sure with the time I had I only scratched the surface of it.ĮM7 also has preconfigured Templates “Power Packs” forĪs well as being FlexPod and Vblock ratified Likewise EM7 can integrate with a ticketing system like remedy. Once all the Asset Record information has been populated EM7 can be configured to populate standard asset management solutions like Configuration Management Database (CMDB) But have been informed that assuming these detail are available from the API, ScienceLogic will be adding additional asset information in a new release of the UCS Power Pack.
Sciencelogic em7 review serial number#
I noticed that most of the above fields needed to be manually populated, which I can fully appreciate for variable details like “Owner” Details, but was surprised that details like Serial Number were not auto populated. Once the Cisco UCS System is discovered statistics and parameters of each entity are collected.Įach entity has an associated “Asset Record” which contains info likeĪnd loads of other info as well as a free text section for other vital or relevant info There is also a “Cisco UCS Central” Power-Pack which gives visibility and statistics from a UCS Central instance.
Each entity can be drilled into for ever increasing granular information. I really liked the layout of the Cisco UCS Topology as it clearly shows all the components and the current state via Colour codes. Once the Cisco UCS has been discovered it will appear as a monitored device as shown below:
Sciencelogic em7 review how to#
ScienceLogic has a Cisco UCS “Power-Pack” which is a pre-configured template which knows how to discover and monitor Cisco UCS.
Sciencelogic em7 review manual#
I would need to make a manual association between the Blade and the Exchange Entity.īut just to clarify EM7 would do a thorough job at monitoring the application and running test transactions against the particular application to ensure the application is running within the defined parameters. The answer was “Yes”, but at present this would be a manual merge exercise, i.e. is the system clever enough to know that my Exchange server is running on Blade X, which has just started reporting memory problems. Now one of my questions was that “if I had an issue/fault with a blade, would that issue show up as a potential impact to my Application” i.e. So while this may be seen as a licensing “inefficiency”, I can see the logic and value in having these entities split out.
the Blade will be monitored for x and the ESXi Host Monitored for Y. Now these 2 entities may all represent the same logical workload, but will be separately licensed and monitored for statistics pertinent to that particular entity, i.e.
Sciencelogic em7 review password#
To define settings like Hostname, Admin Username and Password and IP address.Īgain very easy just browse to the IP address of the virtual appliance port number 7700 download your reg file, E-mail the reg file off to ScienceLogic and they mail back the licence file which you then just upload in the same screen.ĮM7 is licensed on a “per Monitored entity” basis, so as an example the system will detect and monitor a Cisco UCS Blade and VMware ESXi Host.
Sciencelogic em7 review iso#
I created a Virtual Machine with the recommended specs, 8GB RAM, Mounted the supplied ScienceLogic ISO then went through the very easy wizard driven initial install. I choose the All-in-One option, where all components reside on the same virtual appliance.
ScienceLogic EM7 supports a distributed model or a Stand-a-lone “All-in-One” Model for smaller environments. EM7 Version Evaluated Version used 7.2.2.6.Cisco UCS C 200 Running the ScienceLogic and Cisco UCS Central Appliances.Cisco UCS B Series 2 Chassis (4xB200M2, 4xB250M2).The Lab setup I will use for all these evaluations is shown below. Plus in my view this shows a good indication of customer service, and makes a change from the “Just download an Eval and get back to us with any questions” type attitudes. While not particular difficult it does make my life a whole lot easier, and gives me an opportunity to ask all the questions I might have. OK so after what seems like an age, I have finally managed to get round to blogging down my initial thoughts on the first Monitoring Solution I have evaluated.ĭisclosure: This review has not been sponsored in any way, and is just my opinionįirstly big thanks to Mike Riley and Ray Wood of ScienceLogic for coming in and running me through the setup and initial config of EM7. For more infomation and to obtain your own EM7 eval visit the ScienceLogic Web-Site